Product Desc
Specifications
One unit supply floor heating, hot water and cooling, high efficiency. Enjoy floor heating during cold time, cool air in summer time and hot water at all seasons. Redefine comfortable home life.
Adopting the international brand ‘Copeland" Enhanced Vapor Injection (EVI) ZW series compressor, it is suitable for running in ultra-low temperature environment. Ensure the heating efficiency ratio in ultra-low temperature environment. With Compressor Crankcase Heating Tape, new economizer and heating chassis configuration, "Dual-core power“ provides rapid heating.
Apply Sanhua new generation electronic expansion valve to relize automatic temperature adjustment in the cryogenic environment; no only improve the efficiency but also protect the life time of comressor effectively,.
No need to be on duty, automation, automatic water supply, heating and power off. Over 100 meters long distance control, automatic fault diagnosis, power off memory functions etc.
Remark:1..Before starting the main unit, it is necessary to ensure that there is sufficient water in the transition tank to operate.
2.When power off in winter, water must be drained out rom the pipes to revent the cracking of the water pipes
-12℃ Working condition |
Floor Heating | Hot Water | Cooling | |||||||||||||||||
Model |
Heating Capacity (KW) |
Input Power (KW) |
Current (A) |
Heating Capacity (KW) |
Input Power (KW) |
Current (A) |
Heating Capacity (KW) |
Input Power (KW) |
Current (A) |
Heating Capacity (KW) |
Input Power (KW) |
Current (A) |
Voltage (V) |
Refrgerant |
Auciliary Heater (KW) |
Unit Size (mm) |
Noise (dBA) |
Net Weight (kg) |
Gross Weight (kg) |
Connectopm Diameter (mm) |
RS-11D | 5.9 | 2.65 | 12 | 9.3 | 2.9 | 13.2 | 11.5 | 2.8 | 12.3 | 7 | 2.6 | 11.8 | 220 | R470C | 3 | 500x772x1273 | 58 | 115 | 135 | DN25 |
RS-18D | 9 | 4 | 18.2 | 14 | 4.4 | 20 | 18.5 | 4.6 | 20.9 | 11.5 | 4.1 | 18.7 | 220 | R470C | 3 | 500x1343x1273 | 60 | 176 | 206 | DN25 |
RS-20D | 11.5 | 5.2 | 23.6 | 17.5 | 5.5 | 25 | 23 | 5.6 | 24.6 | 14 | 5.2 | 23.6 | 220 | R470C | 3 | 500x1343x1273 | 62 | 205 | 235 | DN25 |
Remark:
1.The working condition of -12℃ data is tested at dry-bulb temperature -12℃, web-bulb temperature -14℃,water outlet temperature 41℃;
2.Floor heating testing condition at dry-bulb temperature 7℃, web-bulb temperature 6℃, water input temperature 40℃, water outlet temperature 45℃;
3.Hot water testing condition at dry-bulb temperature 20℃, web-bulb temperature 15℃,water initial temperature 15℃, water outlet temperature 55℃;
4.For cold area unit, there is ultra low temperature refrigerant system, the lowest operation temperature is at -25℃;
5. Cooling testing condition at dry-bulb temperature 35℃, web-bulb temperature 24℃, water initial temperature 12℃, water outlet temperature 7℃;
*Specifications shall be subject to change without notice. The detail data of the product shall be preferentially based on the nameplate of the product.